Home Back My Cart : 0 item(s)

 

Keysight (Agilent) E5071C 8.5 GHz, 4 Port Network Analyzer

Keysight (Agilent) E5071C  8.5 GHz, 4 Port Network Analyzer
Price: $39,995.00
Product ID : Keysight (Agilent) E5071C 8.5 GHz, 4 Port Network Analyzer
Manufacturer: KEYSIGHT

Purchase

Description

Keysight (Agilent) E5071C 8.5 GHz, 4 Port Network Analyzer The E5071C is an 8.5 GHz Network Analyzer from Agilent. A network analyzer is a powerful instrument that measures linear characteristics of radio frequency devices with unparalleled accuracy. A range of industries use network analyzers to test equipment, measure materials, and monitor the integrity of signals. Calibrations None NIST Traceable + $825.00 NIST Traceable With Full Data + $862.50 ISO IEC 17025 Accredited + $900.00

Products You May Like

  • Fluke 1550c Megger 5KV Insulation Resistance Tester

    Fluke 1550c Megger 5KV Insulation Resistance Tester $4,995.00

    Fluke 1550c Megger 5KV Insulation Resistance Tester The new 1555 and redesigned Fluke 1550C insulation resistance testers making them ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables. Fluke insulation testers can now conduct the entire range of test voltages specified in IEEE 43-2000 with a best in class. With measurement storage and PC interface, the 1555 and 1550C are perfect tools for preventative or predictive maintenance programs designed to identify potential equipment failures before they occur. Test Voltages Up to 10 kV Provides Solutions for all Applications Voltage Breakdown Detection Alerts the User That Voltage is Present and Gives the Voltage Reading Up to 600 V AC or DC Selectable Test Voltages in 50 V Steps from 250-1000 V, and 100 V Steps 1000 V Measurements Can Be Stored in Up to 99 Memory Locations, with Each Location Assigned a Unique, User Defined, Label for Easy Recall Long Battery Life Gives the User Over 750 Tests Between Charges Automatic Calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with No Additional Setup Guard System Eliminates the Effect of Surface Leakage Current on High-Resistance Measurements Large Digital/Analog LCD for Easy Viewing Capacitance and Leakage Current Measurement Ramp Function for Breakdown Testing Resistance Measurements Up to 2 T? Timer Settings Up to 99 Minutes for Timed Tests CAT IV 600 V Safety Rating Electrical Specifications The tester's accuracy is specified for one year after calibration at operating temperatures of 0°C to 35°C. For operating temperatures outside the range (-20°C to 0°C and 35°C to 50°C), add ± .25% per °C, except on the 20% bands add ± 1% per °C. Insulation Resistance Measurement Test voltage (DC) 250 VRange< 250 kΩ, 250 kΩ to 5 GΩ 5 GΩ to 50 GΩ > 50 GΩ Accuracy (± reading)Unspecified 5% 20% Unspecified 500 VRange< 500 kΩ 500 kΩ to 10 GΩ 10 GΩ to 100 GΩ > 100 GΩ Accuracy (± reading)Unspecified 5% 20% Unspecified 1000 VRange< 1 MΩ 1 MΩ to 20 GΩ 20 GΩ to 200 GΩ > 200 GΩ Accuracy (± reading)Unspecified 5% 20% Unspecified 2500 VRange< 2.5 MΩ 2.5 MΩ to 50 GΩ 50 GΩ to 500 GΩ > 500 GΩ Accuracy (± reading)Unspecified 5% 20% Unspecified 5000 VRange< 5 MΩ 5 MΩ to 100 GΩ 100 GΩ to 1 TΩ > 1 TΩ Accuracy (± reading)Unspecified 5% 20% Unspecified Bar graph range0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555) Insulation test voltage accuracy-0%, +10% at 1 mA load current Induced AC mains current rejection2 mA maximum Charging rate for capacitive load5 seconds per μF Discharge rate for capacitive load1.5 s/μF Leakage current measurementRange1 nA to 2 mA Accuracy± (5% + 2 nA) Capacitance measurementRange0.01 μF to 15.00 μF Accuracy± (15% rdg + 0.03 μF) TimerRange0 to 99 minutes Resolution setting1 minute Resolution indication1 second Live circuit warningWarning range30 V to 660 V AC/DC, 50/60 Hz Voltage accuracy± (15% + 2 V) Software specificationsFlukeView Forms™ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8. General Specifications Display75 x 105 mm Power12 V lead-acid rechargeable battery, Yuasa NP2.8-12 Charger Input (AC)85 V to 250 V AC 50/60 Hz 20 VA This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only. Dimensions269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in) Weight3.7 kg (8.2 lb) Temperature (operating)-20°C to 50°C (-4°F to 122°F) Temperature (storage)-20°C to 65°C (-4°F to 149°F) Humidity80% to 31°C decreasing linearly to 50% at 50°C Altitude2000 m Enclosure sealingIP40 Input overload protection1000 V AC Electromagnetic compatibilityEN 61326 Safety complianceIEC 61010-1: Overvoltage category II, Pollution Degree 2. IEC 61010-2-030: Measurement 600V CAT IV / 1000V CAT III IEC 61557-1, IEC 61557-2

Call us: 972-984-2057

Full Website