Manufacturers

Newsletter

Fluke VT PLUS HF Gas Flow Analyzer

Fluke VT PLUS HF Gas Flow Analyzer
Click to enlarge
Price: $9,950.00
Product ID : Fluke VT PLUS HF Gas Flow Analyzer
Manufacturer: FLUKE
E-mail to a friend

Purchase

Description

Fluke VT PLUS HF Gas Flow Analyzer VT PLUS HF Gas Flow Analyzer The VT PLUS HF is Fluke Biomedical’s premier general-purpose gas-flow analyzer. In addition, special display modes and bi-directional flow make it perfect for fully and efficiently testing both conventional mechanical ventilators and high-frequency ventilators. EC.6.20 now requires 100 % completion of scheduled life-support device preventive maintenance every year, and VT PLUS HF can help meet those requirements. Multiple special-function tests make troubleshooting quick and efficient. VT PLUS HF has the capability to measure either high- or low-flow and pressure, replacing the need for gauges and flow meters. It measures 21 ventilator parameters and can display all of them on one screen. Results can be printed directly from the unit or from a PC with included Windows-compatible software. VT PLUS HF also has onboard graphing capability and shows the minimum, maximum, average, and absolute measurement for all parameters. Learning to use the VT PLUS HF is simple. Technicians control the unit using the VT PLUS HF user-friendly command system, or, if they’re familiar with the RT-200, they can switch to a special control mode that uses RT-200-style commands. VT PLUS HF can be operated with a variety of precision simulation lungs to ensure that ventilators are tested to manufacturers’ specifications and clinical expectations with a fully NIST-traceable testing system Key Features Bi-directional flow, pressure, volume, and oxygen concentration, and pressure measurements Low- and high-pressure, and flow measurement capability Special HF mode—up to 900 BPM (15 Hz) RS-232 and printer ports Included Windows-compatible graphics software All 21ventilator parameters displayed at once on one screen Operation by user-friendly VT PLUS HF command mode or special RT-200 command mode Minimum, maximum, average, absolute, and graph for all parameters Multiple special-function tests for efficient troubleshooting Optional Features Operation with a variety of precision simulation lungs available from Fluke Biomedical to complete a fully NIST-traceable ventilator testing system Specifications Power 100 V ac to 240 V ac, 50/60 Hz Maximum Over-Voltage:264 Vac Display 320 x 240 LCD with CFL backlight Viewing Area:10.1 cm x 8.2 cm (3 in x 4 in) Blue on white background Operational Modes Manual mode, for simple tests or troubleshooting Computer-control mode, using RS-232 serial port for special applications Use of VT PLUS HF with VT Plus for Windows, for recording graphs and logging data to a computer Oxygen Measurement Range:0 % to 100 % Accuracy:±2 % FSO Resolution:0.1 % O2 Transducer Location:Internal Gas Compatibility Air, O2, CO2, N2, N2O, He, mixtures or user-defined Gas Reference Units ATP, STPD0, STPD21 and BTPS Output Ports RS-232 serial port and parallel printer port Test Parameters Continuous Flow:Low Flow: ± (2 % of reading and 1 % of range) High Flow: ± (2 % of reading and 1 % of range) Volumetric Flow: Low-Flow: Flow Range: -25 lpm to 25 lmp Accuracy: ± 1 % of range Frequency Response:> 25 Hz or t10-90 < 40 ms, whichever is greater Low Flow Dropout: 0.01 lpm Breath-Defect Threshold: 0.5 lpm Maximum-Flow Rate: 50 lpm Volume Range:> ± 60 L Sample Rate: 100 Hz Resolution: 0.01 lpm flow> 1 lpm; 0.001 lpm flow < 1 lpm Dynamic resistance: < 2.5 cmH2O @ 5 lpm Fittings: 15 mm OD, 1:40 conical male; 0.25 in NPT ID per ASTM F-1054 aluminum with black anodized finish Notes: Tidal-volume accuracy: ± 3 % of reading or ± 2 ml, whichever is greater Volume accuracy tested to 1 liter Flow accuracy is specified for dry air or oxygen Below 3.0 lpm, measurement accuracy is obtained by allowing the VT PLUS HF to fully warm up or manually zeroing before reading or documenting measurement High-Flow: Flow Range: -300 lpm to 300 lmp Accuracy: ± 2 % of reading or ± 2 % of range, whichever is greater Frequency Response:> 25 Hz High-Flow Dropout: 25 lpm Breath-Detect Threshold: 2 lpm Maximum-Flow Rate: 500 lpm Volume Range:> ± 60 L Dynamic Resistance: < 2 cmH2O @ 60 lpm Sample Rate: 100 Hz Resolution: 0.01 lpm Fittings: 22 mm OD, 1:40 conical male; 15 mm ID, 1:40 conical female per ASTM F-1054 aluminum with black anodized finish Notes: Tidal-volume accuracy: ± 3 % of reading or ± 10 ml, whichever is greater Volume accuracy tested to 7 liters Flow accuracy is specified for dry air or oxygen Low-Pressure: Range: ± 500 mmHg (10 psi) Accuracy: ± 0.8 % of reading or ± 1.5 mmHg, whichever is greater Frequency Response:> 10 Hz Resolution: 0.1 mmHg Fittings: Luer lock, stainless steel Maximum Applied Pressure: 60 psi Sample Rate: 100 Hz Operating Pressure: 30 psi Note: Fluid pressure may be applied to the positive port; however, fluids should be kept from entering the pressure port by using a suitable length of connection tubing High-Pressure: Maximum Applied Pressure: 150 psi Range: ± 100 psi Accuracy: ± 1 % of reading or ± 0.3 psig, whichever is greater Frequency Response:> 10 Hz Resolution: 0.1 psi Sample Rate: 100 Hz Fittings: DISS connector, stainless steel Airway-Pressure: Maximum Applied Pressure: 20 psi Range: ± 120 cmH2O Accuracy: ± 0.75 % of reading or ± 0.5 cmH2O, whichever is greater Frequency Response:> 25 Hz or t10-90 < 40 ms, whichever is greater Resolution: 0.1 cmH2O Fittings: Internally connected at the transducer distal end Note: Airway pressure is internally tapped off the proximal-flow sensor port, which is the port closest to the exhaust port on the VT PLUS HF Ventilator Parameter Inspiratory and Expiratory Tidal Volume:Range:As specified in high-flow/low-flow spec Accuracy: As specified in high-flow/low-flow spec Expiratory Minute VolumeRange: 0 L to 60 L Accuracy: ± 3 of % or 250 ml Breath RateRange: 0.5 BPM to 150.0 BPM Accuracy:± 1 of % Inspiratory-to-Expiratory Time Ratio (I:E Ratio):Range: 1:200 to 200:1 Accuracy: ± 2 % or ± 0.1 s Inspiratory Time:Range: 0 s to 60 s Accuracy: ± 1 % or ± 0.1 s Expiratory Time:Range: 0 s to 90 s Accuracy: ± 1 % or ± 0.1 s Peak Inspiratory Pressure:Range: ± 120 cmH2O Accuracy: ± 3 % or ± 1 cmH2O Inspiratory Pause Pressure:Range: ± 120 cmH2O Accuracy: ± 3 % or ± 1 cmH2O Mean Airway Pressure:Range: ± 80 cmH2O Accuracy: ± 3 % or ± 0.5 cmH2O Positive End-Expiratory Pressure (PEEP):Range: -5 to 40 cmH2O Accuracy: ± 3 % or ± 0.5 cmH2O Lung Compliance:Range: 0 to 150 ml/cmH2O Accuracy: ± 5 % or ± 5 ml/cmH2O Inspiratory Hold Time:Range: 0 s to 60 s Accuracy: ± 1 % or ± 0.1 s Expiratory Hold Time:Range: 0 s to 90 s Accuracy: ± 1 % or ± 0.1 s Peak Expiratory Flow:Range: 0 lpm to 300 lpm Accuracy: ± 3 % or ± 2 lpm Peak Inspiratory Flow:Range: 0 lpm to 300 lpm Accuracy: ± 3 % or ± 2 lpm Flow Bias:Range: 0 lpm to 30 lpm Accuracy: ± 2 % or ± 0.5 lpm Operating Environment Conditions Temperature Range:10 °C to 40 °C Ambient Humidity:0 % to 80 % noncondensing to 31 °C, decreasing to 50 % at 40 °C Barometric Pressure:8 psig to 18 psig Storage Environment Conditions Temperature Range:-25 °C to -50 °C Humidity:0 to 95 % noncondensing Dimensions (WxDxH) 25.4 cm x 25.4 cm x 12.7 cm (10 in x 10 in x 5 in) Weight 4.53 kg (10 lb) VT+HF-US120VT PLUS HF Gas-Flow Analyzer – United States, 120 V All models include the following: Operator's manual VT for Windows PC Software (8830200FG) Serial cable (75034) Tilt stand (1HD0011) Power cord (country specific) Accessory kit (to include the following 16 accessories) (VT-PLUS-7001) Filter, external (bacterial) (one each) Filter, external (60mm/low flow) (one each) Filter, external (pulmonary function) (one each) Adapter, DISS O2 nut and nipple with 1/4" I.D. hose barb (one each) Tubing adapter, directional (15mm OD x 15mm OD) (two each) Tubing adapter (22mm OD x 22mm ID) (two each) Tubing adapter (22mm OD x 22mm OD) (two each) Tubing adapter (15mm OD x 22mm OD) (two each) Tubing adapter (15mm OD x 15mm OD) (two each) Tubing adapter (15mm ID x 15mm OD) (two each) Tubing adapter, narrow bore (two each) Barb (luer lock – male to 1/89 ID tubing) (two each) Tubing adapter (1/4 NPT male to 1/8 ID tubing barb fitting) (two each) Tubing adapter (luer lock 1/16 to bulkhead connection) (two each) Fuse (500 mA) Tubing 1/8" 4' long (two each) VT+HF/ACCULUNG-US VT PLUS HF Gas-Flow Analyzer/ACCU LUNG – United States Includes: Premium Precision Ventilator Test Kit: VT PLUS HF Gas-Flow Analyzer. AccuLung portable precision lung/soft-sided carrying case for AccuLung. VT+HF-AUS250V VT PLUS HF Gas-Flow Analyzer – Australia, 250 V Includes: VT PLUS HF Gas-Flow Analyzer only VT+HF/ACCULUNG-AUS VT PLUS HF Gas-Flow Analyzer/ACCU LUNG – Australia Includes: Premium Precision Ventilator Test Kit: VT PLUS HF Gas-Flow Analyzer. AccuLung portable precision lung/soft-sided carrying case for AccuLung. VT+HF-SHK250V VT PLUS HF Gas-Flow Analyzer – Schuko, 250 V Includes: VT PLUS HF Gas-Flow Analyzer only VT+HF/ACCULUNG-SHK VT PLUS HF Gas-Flow Analyzer/ACCU LUNG – Schuko Includes: Premium Precision Ventilator Test Kit: VT PLUS HF Gas-Flow Analyzer. AccuLung portable precision lung/soft-sided carrying case for AccuLung. VT+HF-UK250V VT PLUS HF Gas-Flow Analyzer – United Kingdom, 250 V Includes: VT PLUS HF Gas-Flow Analyzer only VT+HF/ACCULUNG-UK VT PLUS HF Gas-Flow Analyzer/ACCU LUNG – United Kingdom Includes: Premium Precision Ventilator Test Kit: VT PLUS HF Gas-Flow Analyzer. AccuLung portable precision lung/soft-sided carrying case for AccuLung. VT+HF-BRA250V VT PLUS HF Gas-Flow Analyzer – Brazil, 250 V Includes: VT PLUS HF Gas-Flow Analyzer only VT+HF/ACCULUNG-BRAZ VT PLUS HF Gas-Flow Analyzer/ACCU LUNG – Brazil Includes: Premium Precision Ventilator Test Kit: VT PLUS HF Gas-Flow Analyzer. AccuLung portable precision lung/soft-sided carrying case for AccuLung. 8831007VT-Plus upgrades (adds FH capability and RT-200 mode) VT PLUS HF hardware and firmware factory service upgrade (for units lower than hardware v1.01.01; additional flat-rate charge required for factory service/calibration) Gas Flow Analyzers ACCULUNG IIAccuLung II Adjustable Portable Precision Test Lung (part# 4281291) ACCU LUNGAccuLung Portable Precision Test Lung (part# 2387318) with soft-sided carrying case 48499Siemens 190 portable precision lung (part# 2213774) Cables 33705123370512 Dual 9DF serial cable (part# 2204472) Special cable to attach to RS232 on a PC. 71072Parallel printer cable, D25M to C36M (part# 2238072) Carrying Cases 9530-0066Multi-purpose Hard-sided Watertight Carrying Case (part# 2248587) (contains pick-and-pluck foam) (19 " L x 14 " W x 7 ¾ " H) 5022010Soft vinyl carrying case (part# 2222822) Miscellaneous Accessories MI-12952Michigan Instruments Non-Instrumented Adult/Infant AccuLung portable precision lung (part# 2251013) MI-14900Michigan Instruments Non-Instrumented Single-Adult AccuLung portable precision lung (part# 2251049) MI-11000Michigan Instruments Non-Instrumented Dual-Adult AccuLung portable precision lung RP RING KITParabolic Airway Resistor Ring kit (part# 3799622) Printers 60196120V Power Supply for Seiko DPU414 printer (part# 2235375) Printer used with the following products: •VT PLUS HF Gas Flow Analyzer •ISA601 Pro SeriesXL •IDA 4 Plus •Index 2XL •QED 6 •BP Pump 2 PRINTR/CTZ-US120VPrinter, 115V, Citizen IDP3110 (part# 2248762) PRINTR/CTZ-US220VPrinter 220V, Citizen IDP3110 Schuko (part# 2719653) 97116Printer paper DPU-414 and DPU-411 (part# 2248737) (minimum 7 rolls – price is per roll) PRINTR/414-US120VPrinter, SEIKO DPU-414-30B (part# 2248899) Includes 120V PWR Supply (part# 2235375) (Note: requires additional purchase of parallel printer cable, part# 2238072) for use with ESA601/IDA 4 Plus/Index 2XL/QED 6/BP Pump 2 PRINTR414-SHK220VPrinter, Seiko DPU-414-30B with 220 V power supply (part# 2399531) (NOTE: requires additional purchase of serial printer cable (part# 3370513) Software ANSUR VTAnsur VT Plug-In license (part# 3837485)

Product Reviews

Login or Register to write the first review.