Datrend Oxitest Plus 7 SpO2 Simulator – with Nellcor® probe

Datrend  Oxitest Plus 7  SpO2 Simulator – with Nellcor® probe
Click to enlarge
Price: $3,950.00
Product ID : Datrend Oxitest Plus 7 SpO2 Simulator – with Nellcor® probe
Manufacturer: Datrend Systems Inc
E-mail to a friend

Purchase

Description

Datrend Oxitest Plus7 SpO2 Simulator – with Nellcor® probe Description The Oxitest Plus 7 features the exclusive Nellcor-Puritan Bennett sensor port, developed in cooperation with Nellcor. This industry exclusive feature allows correct selection of the instrument's simulation output to the specific R-Cal value of the attached Nellcor probe. The Oxitest Plus 7 front panel keyboard design makes the adjustment of the five preset oxygen saturation levels, six preset heart rates and four preset amplitudes a breeze. In addition, features such as Signal Artifact simulations, preset patient parameters, Alarm Testing and Report printing make Oxitest Plus 7 truly unique. The 2x20 character LCD display identifies the oximeter make and model, and includes a status indicator providing user feedback on the test in progress with seven status messages. The internal, rechargeable NiCad battery offers up to 40 hours of continuous use and the unit includes a standard accessory AC adapter. To further enhance your pulse oximeter testing requirements, Oxitest Plus 7 is compatible with our new ES 601Plus and other automated test systems such as the Fluke Biomedical medTester 5000C. Modes of Operation Manual and remote (via PC or automated tester) Oxygen Saturation (SpO2%) Presets 97%, 93%, 90%, 80% and 70% presets for all supported oximeters, 55% SpO2 preset available when testing Nellcor and Nellcor OEM oximeters SpO2 Accuracy ± 1% @ 97%, 93% SpO2 (All supported oximeters) ± 1% @ 90%, 80%, 70% SpO2 (All supported oximeters except Datex, Invivo) ± 2% @ 90%, 80%, 70% SpO2 (Datex, Invivo oximeters) ± 1% @ 55% SpO2 (Nellcor and Nellcor OEMs only) Heart Rate Selections: 20 to 250 beats per minute (BPM) in 1 BPM steps Presets: 30, 60, 90, 120, 180, 240 BPM Accuracy: ± 1 BPM Pulse Amplitude Selections: Zero (no blood flow) to 100% (normal adult pulse) in 1% steps Presets: 100%, 30%, 10% and 5% Accuracy: ± 1% Signal Artifact Movement, Tapping (Spike artifact), Shivering (Tremor artifact) Preset Patient Types The following patient types are preset/programmable, and can be rapidly accessed via the AUTO pushbutton. Normal Adult Hypoxia Tachycardia Bradycardia Low Perfusion No Perfusion Neonate Movement Artifact Tremor (Shivering) Alarm Testing Sequences The Oxitest Plus 7 provides unique alarm testing of your pulse oximeters using the following five automated sequences. It allows measurement of the time needed by the pulse oximeter to automatically self-clear alarms. Alarm tests may also be used programmed via the RS-232 port. 1. Low Sat (SpO2%) - 97>70>97 2. High Rate (BPM) - 72>180>72 3. Low Rate (BPM) - 72>40>72 4. Low Signal (AMP%) - 100>3>100 5. Artifact (Motion) - ON>OFF User Interface Display - 20 character x 2 line Contrast - Externally adjustable Keypad - 15 keys PULSE OX Manufacturer SpO2 Percent Oxygen Saturation HEART RATE (presets) HR ▲ (+1BPM), ▼ (-1BPM) PULSE AMP (presets) PULSE AMP ▲ (+1%), ▼ (-1%) PASS/YES FAIL/NO AUTO (presets) ALARM TEST START/STOP (Alarm Test) ERASE (memory) PRINT Nellcor Port Measures the resistor value in Nellcor-technology based SpO2 sensors and selects the particular pulse oximeter SpO2 calibration curve (R-curve) to best match the characteristics of the sensor. This feature provides High-accuracy testing of Nellcor disposable and re-usable SpO2 sensors. Memory Up to 20 PASS/FAIL manual simulation settings and AUTO & ALARM TEST results are saved in battery-backed, non-volatile memory. Test results in memory can be printed as a TEST REPORT via optional external serial printer or downloaded via RS-232 port to computer. Serial/Printer Interface 5 Pin MiniDIN connector RS-232 Serial Baud Rate: 9600 baud, 8N1 Print: 40-column format ECG Trigger Signal Logic pulse approximates the QRS complex width & timing for testing synchronized SpO2 measurements. Compatible with Nellcor "C-Lock" feature. Output signal: 2.5 Volts (10k-ohm load) Connector: 3.5 mm mini-phone jack Power Supply Battery: - 7.2V NiCad rechargeable Capacity: - 1.4 Ah Life: - 40 hours continuous use Adapters: - North America, Europe, United Kingdom Certification North America: CSA/UL International: IEC 1010:1990/92/95 CE EN 55022:1994 Class B CE EN 610004-3 Level A IEC 801-4 Level B IEC 801-2 Level B Standard Accessories AC Adapter Carrying Case Operating Manual Optional Accessories Serial Printer and cable Serial PC cable

Product Reviews

Login or Register to write the first review.